{"title":"Wood Stove Pipe Kits — Through the Wall \u0026 Through the Roof","description":"\u003cp\u003e\u003cstrong\u003eA wood stove pipe kit covers the connector run — the black pipe you can see, from the stove's flue collar to the wall or ceiling.\u003c\/strong\u003e Beyond that point it becomes Class A insulated chimney, which is a separate purchase and is not included in any kit on this page.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSizing:\u003c\/strong\u003e every kit here is 6\" — the flue collar size on every Drolet and Englander wood stove we sell. Measure your stove's collar before ordering if you have an older appliance.\u003c\/p\u003e\n\n\u003ctable style=\"width:fit-content\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eKit\u003c\/th\u003e\n\u003cth\u003eRoute\u003c\/th\u003e\n\u003cth\u003ePipe\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/drolet-6-black-single-wall-pipe-kit-to-the-ceiling-sp00370\"\u003eSP00370 — To The Ceiling\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight up, through the roof\u003c\/td\u003e\n\u003ctd\u003eSingle wall\u003c\/td\u003e\n\u003ctd\u003e$149\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/vortex-6-to-the-ceiling-double-wall-pipe-kit-vodbktc06\"\u003eVODBKTC06 — To-The-Ceiling\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight up, through the roof\u003c\/td\u003e\n\u003ctd\u003eDouble wall\u003c\/td\u003e\n\u003ctd\u003e$219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/drolet-6-black-single-wall-pipe-kit-to-the-wall-sp00360\"\u003eSP00360 — To The Wall\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOut through an exterior wall\u003c\/td\u003e\n\u003ctd\u003eSingle wall\u003c\/td\u003e\n\u003ctd\u003e$229\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/vortex-6-to-the-wall-double-wall-pipe-kit-vodbktw06\"\u003eVODBKTW06 — To-The-Wall\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eOut through an exterior wall\u003c\/td\u003e\n\u003ctd\u003eDouble wall\u003c\/td\u003e\n\u003ctd\u003e$359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","products":[{"product_id":"vortex-6-to-the-ceiling-double-wall-pipe-kit-vodbktc06","title":"To-The-Ceiling Double Wall Stove Pipe Kit 6\" — VODBKTC06","description":"\u003cp\u003eComplete \u003cstrong\u003e6\" double-wall connector pipe kit\u003c\/strong\u003e for venting a freestanding wood stove straight up through the ceiling.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any wood stove with a 6\" flue collar, regardless of brand.\u003c\/strong\u003e Measure your stove's flue outlet — if it's 6\", this kit connects. The included appliance connector mates the Vortex pipe to your stove collar; build the rest of the run from Vortex components rather than mixing brands.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis kit includes:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAppliance connector (stove adapter)\u003c\/li\u003e\n\u003cli\u003eTelescoping section, 38\"–70\"\u003c\/li\u003e\n\u003cli\u003e36 self-tapping screws\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eVortex double-wall is listed at \u003cstrong\u003e6\" clearance to combustible walls and 6\" to combustible ceilings\u003c\/strong\u003e — versus 18\" for single-wall — and is required by many stove manuals to achieve their listed reduced clearances. Because this kit is built around a telescoping section, the 5\" reduced clearance does \u003cstrong\u003enot\u003c\/strong\u003e apply here; plan the run at 6\". Listed to \u003cstrong\u003eULC S641\u003c\/strong\u003e; install per NFPA 211 (US) or CSA B365 (Canada).\u003c\/p\u003e\u003cp\u003eThis is connector pipe, not chimney. The pipe itself must not pass through the ceiling — a listed ceiling support box and chimney are required at the penetration. Where the pipe clearance and the appliance clearance differ, always use the larger. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eShips via standard parcel. Sold as a complete to-the-ceiling kit.\u003c\/em\u003e\u003c\/p\u003e","brand":"Vortex","offers":[{"title":"Default Title","offer_id":49219255402748,"sku":"VODBKTC06","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/VODBKTC06.webp?v=1782153816"},{"product_id":"vortex-6-to-the-wall-double-wall-pipe-kit-vodbktw06","title":"To-The-Wall Double Wall Stove Pipe Kit 6\" — VODBKTW06","description":"\u003cp\u003eComplete \u003cstrong\u003e6\" double-wall connector pipe kit\u003c\/strong\u003e for venting a freestanding wood stove horizontally out through an exterior wall.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any wood stove with a 6\" flue collar, regardless of brand.\u003c\/strong\u003e Measure your stove's flue outlet — if it's 6\", this kit connects. The included appliance connector mates the Vortex pipe to your stove collar; build the rest of the run from Vortex components rather than mixing brands.\u003c\/p\u003e\u003cp\u003eVortex double-wall is listed at \u003cstrong\u003e6\" clearance to combustible walls and 6\" to combustible ceilings\u003c\/strong\u003e — versus 18\" for single-wall — and is required by many stove manuals to achieve their listed reduced clearances. Because this kit includes an adjustable section, the 5\" reduced clearance does \u003cstrong\u003enot\u003c\/strong\u003e apply here; plan the run at 6\". Listed to \u003cstrong\u003eULC S641\u003c\/strong\u003e; install per NFPA 211 (US) or CSA B365 (Canada).\u003c\/p\u003e\u003cp\u003eThis is connector pipe, not chimney. The pipe itself must not pass through the wall — a listed wall thimble and chimney section are required at the penetration. A pipe hanger is required on any horizontal run over 4 ft, plus one for every 4 ft after that. Where the pipe clearance and the appliance clearance differ, always use the larger. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eShips via standard parcel. Sold as a complete to-the-wall kit.\u003c\/em\u003e\u003c\/p\u003e","brand":"Vortex","offers":[{"title":"Default Title","offer_id":49219287646460,"sku":"VODBKTW06","price":359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/VODBKTW06.webp?v=1782156015"},{"product_id":"drolet-6-tee-with-cap-single-wall-black-pipe-sp00110","title":"6\" Black Single Wall Stove Pipe — Tee with Cap","description":"\u003cp\u003e\u003cstrong\u003eTee with cap\u003c\/strong\u003e for \u003cstrong\u003e6\" single-wall black stove pipe\u003c\/strong\u003e, used where the connector run needs an offset. The removable cap gives access for inspection, maintenance, and cleaning.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any wood stove with a 6\" flue collar, regardless of brand.\u003c\/strong\u003e Measure your stove's flue outlet — if it's 6\", this fits your connector run. Single-wall black pipe is a dimensional standard, not brand-specific.\u003c\/p\u003e\u003cp\u003eMade from \u003cstrong\u003e22 ga welded steel\u003c\/strong\u003e — heavier and sturdier than the 24 ga clip-on pipe sold by many competitors, with a cleaner finished appearance. Carries a limited lifetime warranty.\u003c\/p\u003e\u003cp\u003eSingle-wall connector pipe requires an \u003cstrong\u003e18\" clearance to combustibles\u003c\/strong\u003e. With approved SBI shielding, US clearances drop to \u003cstrong\u003e6\" to side walls and 9\" to the ceiling\u003c\/strong\u003e (9\" to walls if shielding other than SBI's is used) — see the \u003ca href=\"\/products\/heat-shield-kit-for-6-black-single-wall-stove-pipe-to-the-ceiling\"\u003e6\" single-wall heat shield kit\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSingle-wall pipe must not pass through a wall or ceiling, must not be used outdoors, and is \u003cstrong\u003enot permitted in mobile homes\u003c\/strong\u003e. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Drolet","offers":[{"title":"Default Title","offer_id":49266085232892,"sku":"SP00110","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/SP00110-SP00111-SP00112.jpg?v=1783652999"},{"product_id":"drolet-6-black-round-wall-trim-collar-sp00150","title":"6\" Black Round Wall Trim Collar","description":"\u003cp\u003e\u003cstrong\u003eRound trim collar\u003c\/strong\u003e in black, sized to fit around \u003cstrong\u003e6\" single-wall stove pipe\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any 6\" single-wall stove pipe run, regardless of stove brand.\u003c\/strong\u003e Sized to the outside diameter of 6\" pipe, so it works with any 6\" single-wall connector run.\u003c\/p\u003e\u003cp\u003eIt conceals the gap where the pipe meets the wall or ceiling, giving the finished installation a clean, professional look.\u003c\/p\u003e\u003cp\u003eA trim collar is cosmetic and does \u003cstrong\u003enot\u003c\/strong\u003e reduce any clearance. Single-wall connector pipe still requires an \u003cstrong\u003e18\" clearance to combustibles\u003c\/strong\u003e unless approved SBI shielding is installed — see the \u003ca href=\"\/products\/heat-shield-kit-for-6-black-single-wall-stove-pipe-to-the-ceiling\"\u003e6\" single-wall heat shield kit\u003c\/a\u003e. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Drolet","offers":[{"title":"Default Title","offer_id":49266085462268,"sku":"SP00150","price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/SP00150-SP00151-SP00152.jpg?v=1783653010"},{"product_id":"drolet-6-black-square-wall-trim-collar-sp00170","title":"6\" Black Square Wall Trim Collar","description":"\u003cp\u003e\u003cstrong\u003eSquare trim collar\u003c\/strong\u003e in black, sized to fit around \u003cstrong\u003e6\" single-wall stove pipe\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any 6\" single-wall stove pipe run, regardless of stove brand.\u003c\/strong\u003e Sized to the outside diameter of 6\" pipe, so it works with any 6\" single-wall connector run.\u003c\/p\u003e\u003cp\u003eIt conceals the gap where the pipe meets the wall or ceiling, giving the finished installation a clean, professional look.\u003c\/p\u003e\u003cp\u003eA trim collar is cosmetic and does \u003cstrong\u003enot\u003c\/strong\u003e reduce any clearance. Single-wall connector pipe still requires an \u003cstrong\u003e18\" clearance to combustibles\u003c\/strong\u003e unless approved SBI shielding is installed — see the \u003ca href=\"\/products\/heat-shield-kit-for-6-black-single-wall-stove-pipe-to-the-ceiling\"\u003e6\" single-wall heat shield kit\u003c\/a\u003e. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Drolet","offers":[{"title":"Default Title","offer_id":49266085527804,"sku":"SP00170","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/SP00170-SP00171-SP00172.jpg?v=1783653014"},{"product_id":"drolet-6-black-single-wall-pipe-kit-to-the-wall-sp00360","title":"6\" Black Single Wall Stove Pipe Kit — To The Wall","description":"\u003cp\u003eComplete \u003cstrong\u003e6\" single-wall black stove pipe kit\u003c\/strong\u003e for venting a freestanding wood stove horizontally out through the wall.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any wood stove with a 6\" flue collar, regardless of brand.\u003c\/strong\u003e Measure your stove's flue outlet — if it's 6\", this kit connects. Single-wall black pipe is a dimensional standard, not brand-specific.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis kit includes:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTwo 12\"L pipe sections\u003c\/li\u003e\n\u003cli\u003eOne 24\"L pipe section\u003c\/li\u003e\n\u003cli\u003eOne telescoping stove pipe, 14\"–22\"L\u003c\/li\u003e\n\u003cli\u003eOne stove connector\u003c\/li\u003e\n\u003cli\u003eTwo 45° elbows\u003c\/li\u003e\n\u003cli\u003eOne square wall trim collar\u003c\/li\u003e\n\u003cli\u003e36 self-tapping screws\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSingle-wall connector pipe requires an \u003cstrong\u003e18\" clearance to combustibles\u003c\/strong\u003e. With approved SBI shielding, US clearances drop to \u003cstrong\u003e6\" to side walls and 9\" to the ceiling\u003c\/strong\u003e (9\" to walls if shielding other than SBI's is used) — see the \u003ca href=\"\/products\/heat-shield-kit-for-6-black-single-wall-stove-pipe-to-the-ceiling\"\u003e6\" single-wall heat shield kit\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eThe pipe itself must not pass through the wall — a listed wall pass-through or chimney section is required at the penetration. Single-wall pipe must not be used outdoors and is \u003cstrong\u003enot permitted in mobile homes\u003c\/strong\u003e. Keep the total straight run under 10 ft including elbows, use no more than two 90° elbows, and support any horizontal run over 3 ft. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Drolet","offers":[{"title":"Default Title","offer_id":49266085691644,"sku":"SP00360","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/SP00360.jpg?v=1783653033"},{"product_id":"drolet-6-black-single-wall-pipe-kit-to-the-ceiling-sp00370","title":"6\" Black Single Wall Stove Pipe Kit — To The Ceiling","description":"\u003cp\u003eComplete \u003cstrong\u003e6\" single-wall black stove pipe kit\u003c\/strong\u003e for venting a freestanding wood stove straight up through the ceiling.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any wood stove with a 6\" flue collar, regardless of brand.\u003c\/strong\u003e Measure your stove's flue outlet — if it's 6\", this kit connects. Single-wall black pipe is a dimensional standard, not brand-specific.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis kit includes:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOne telescoping stove pipe, 38\"–70\"L\u003c\/li\u003e\n\u003cli\u003eOne stove connector\u003c\/li\u003e\n\u003cli\u003e36 self-tapping screws\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSingle-wall connector pipe requires an \u003cstrong\u003e18\" clearance to combustibles\u003c\/strong\u003e. With approved SBI shielding, US clearances drop to \u003cstrong\u003e6\" to side walls and 9\" to the ceiling\u003c\/strong\u003e (9\" to walls if shielding other than SBI's is used) — see the \u003ca href=\"\/products\/heat-shield-kit-for-6-black-single-wall-stove-pipe-to-the-ceiling\"\u003e6\" single-wall heat shield kit\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eThe pipe itself must not pass through the ceiling — a listed ceiling support box and chimney are required at the penetration. Single-wall pipe must not be used outdoors and is \u003cstrong\u003enot permitted in mobile homes\u003c\/strong\u003e. Keep the total straight run under 10 ft including elbows. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Drolet","offers":[{"title":"Default Title","offer_id":49266085757180,"sku":"SP00370","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/SP00370.jpg?v=1783653039"},{"product_id":"vortex-6-double-wall-tee-with-cap-vod0110","title":"Vortex Double Wall Tee with Cap 6\" — VOD0110","description":"\u003cp\u003e\u003cstrong\u003eTee with cap\u003c\/strong\u003e for \u003cstrong\u003e6\" Vortex double-wall black pipe\u003c\/strong\u003e (7\" outer diameter), used where the connector run needs an offset. The removable cap gives access for inspection, maintenance, and cleaning. Tee cap included.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any wood stove with a 6\" flue collar, regardless of brand.\u003c\/strong\u003e Measure your stove's flue outlet — if it's 6\", this fits a Vortex connector run. Double-wall pipe is system-specific at the joints, so build the whole run from Vortex components rather than mixing brands.\u003c\/p\u003e\u003cp\u003eThe stainless-steel inner wall uses an exclusive \u003cstrong\u003ethermal weave\u003c\/strong\u003e that promotes even airflow and lower outer-wall temperatures. Joints are laser-welded and the metallic black powder coat resists corrosion.\u003c\/p\u003e\u003cp\u003eVortex double-wall is listed at \u003cstrong\u003e6\" clearance to combustible walls and 6\" to combustible ceilings\u003c\/strong\u003e — versus 18\" for single-wall — and is required by many stove manuals to achieve their listed reduced clearances. An assembled run with no adjustable section may be installed at \u003cstrong\u003e5\"\u003c\/strong\u003e. Listed to \u003cstrong\u003eULC S641\u003c\/strong\u003e; install per NFPA 211 (US) or CSA B365 (Canada).\u003c\/p\u003e\u003cp\u003eThis is connector pipe, not chimney. It must not pass through a wall, ceiling, floor, attic or closet, and must not be enclosed. Where the pipe clearance and the appliance clearance differ, always use the larger. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Vortex","offers":[{"title":"Default Title","offer_id":49266088444156,"sku":"VOD0110","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/VOD0110.jpg?v=1783653126"},{"product_id":"vortex-6-wall-finishing-band-vod0150","title":"Vortex Wall Finishing Band 6\" — VOD0150","description":"\u003cp\u003e\u003cstrong\u003e6\" Vortex wall finishing band\u003c\/strong\u003e, used where \u003cstrong\u003edouble-wall black stove pipe\u003c\/strong\u003e meets a 2100-class chimney pipe at a cathedral support box or wall pass-through.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFits any 6\" Vortex double-wall run, regardless of stove brand.\u003c\/strong\u003e Sized to 6\" Vortex double-wall pipe (7\" outer diameter) — it is a Vortex system part and is not intended for another manufacturer's double-wall pipe.\u003c\/p\u003e\u003cp\u003eIt slides over the universal adapter up to the end of the double-wall pipe, concealing the transition for a clean, finished look. Metallic black powder coat matches the Vortex double-wall pipe.\u003c\/p\u003e\u003cp\u003ePart of the Vortex double-wall system. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Vortex","offers":[{"title":"Default Title","offer_id":49266088509692,"sku":"VOD0150","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/VOD0150.jpg?v=1783653138"},{"product_id":"vortex-double-wall-masonry-adapter-6-vod0230","title":"Vortex Double Wall Masonry Adapter 6\" — VOD0230","description":"\u003cp\u003e\u003cstrong\u003e6\" Vortex double-wall masonry adapter\u003c\/strong\u003e, used where the connector run enters an existing masonry chimney through a non-combustible wall.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorks with any 6\" Vortex double-wall run, regardless of stove brand.\u003c\/strong\u003e It joins the connector pipe to the masonry chimney, not to the stove — so what matters is that your run is 6\" Vortex double-wall.\u003c\/p\u003e\u003cp\u003eThe adapter fits into the chimney opening and the collar fastens to the masonry face with screws and anchors (not supplied). Seal the collar-to-masonry joint with high-temperature silicone. On a relined chimney, slide the adapter onto the tee take-off by at least 2\".\u003c\/p\u003e\u003cp\u003ePart of the Vortex double-wall system, listed to \u003cstrong\u003eULC S641\u003c\/strong\u003e at \u003cstrong\u003e6\" clearance to combustible walls and ceilings\u003c\/strong\u003e. Install per NFPA 211 (US) or CSA B365 (Canada). Use only Vortex double-wall components — do not mix with another manufacturer's pipe.\u003c\/p\u003e\u003cp\u003eHave the masonry chimney inspected by a professional sweep or fire inspector before connecting to it. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e","brand":"Vortex","offers":[{"title":"Default Title","offer_id":50912154747132,"sku":"VOD0230","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/VOD0230.jpg?v=1786121482"},{"product_id":"heat-shield-kit-for-6-black-single-wall-stove-pipe-to-the-ceiling","title":"Heat Shield Kit for 6\" Black Single Wall Stove Pipe — To The Ceiling","description":"\u003cp\u003e\u003cstrong\u003eHeat shield kit for 6\" black single-wall stove pipe\u003c\/strong\u003e, to-the-ceiling configuration. This is the part that lets you put a single-wall pipe run close to a wall.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it matters:\u003c\/strong\u003e bare single-wall connector pipe requires \u003cstrong\u003e18\" clearance to combustibles\u003c\/strong\u003e. With approved SBI shielding installed, US clearances drop to \u003cstrong\u003e6\" to side walls and 9\" to the ceiling\u003c\/strong\u003e — a 67% reduction at the walls. If shielding other than SBI's is used, the wall clearance is 9\" instead of 6\".\u003c\/p\u003e\u003cp\u003eThe shield mounts to the pipe on non-combustible spacers, holding a 1\" air gap. SBI single-wall pipe is certified to \u003cstrong\u003eULC S641 only when installed with SBI shielding\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eClearance reduction applies to the \u003cstrong\u003epipe\u003c\/strong\u003e. Your stove's own minimum clearances still apply in full and are never reduced by shielding the pipe — where the two differ, use the larger. Single-wall pipe must not pass through a wall or ceiling, must not be used outdoors, and is \u003cstrong\u003enot permitted in mobile homes\u003c\/strong\u003e. Always confirm the connector pipe type and clearances specified in your stove's installation manual.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eShips via standard parcel.\u003c\/em\u003e\u003c\/p\u003e","brand":"SBI","offers":[{"title":"Default Title","offer_id":50913423393020,"sku":"SP00390","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/9944\/0892\/files\/SP00390.jpg?v=1786121551"}],"url":"https:\/\/stovesource.com\/collections\/wood-stove-pipe-kits.oembed","provider":"StoveSource","version":"1.0","type":"link"}